LogoGLEAM

Your Building's
First Impression
Is Measured In
Fingerprints
Per Square Foot.

Connaught Place · Aerocity · Golf Course Road · Defence Colony

850+

Buildings Cleaned

IRATA

Grade II Certified

₹5 Cr

Insurance Coverage

Gleam rope-access technician in harness descending glass curtain-wall façade, squeegee mid-stroke against Delhi skyline

Ready to Schedule?

Site surveys completed within 48 hours.

Book Free Survey
01 /

Four Stages.
Zero Compromises.

Every Gleam crew follows the same documented protocol on a 32nd-floor curtain wall as on a ground-floor showroom. The sequence is non-negotiable because Delhi's construction dust, monsoon grime, and hard water demand a system — not a routine.

01

Pre-Rinse

High-pressure deionised water flush removes loose dust, bird deposits, and construction particulate from the glass surface and frame joints.

Pressure: 800–1200 PSI · Water: DI-filtered, <10 PPM TDS

02

Agitation

pH-neutral, low-foam detergent is worked into the glass with boar-bristle scrubbers or microfibre sleeves, targeting mineral deposits and silicone staining.

Dwell time: 90 sec · Solution: ISO 9001 certified concentrate

03

Extraction

Straight-pull squeegee technique with zero-residue silicone rubber removes contaminated solution in a single stroke — no re-wetting, no cross-contamination.

Ettore Pro channels · Replaced every 3,000 sq ft

04

Spot-Free Rinse

Final pure-water rinse using reverse-osmosis fed water eliminates all dissolved solids, leaving glass that dries without watermarks under Delhi's hard water conditions.

RO water: <5 PPM · Air-dried · No chamois contact

Window cleaning technician using professional squeegee with proper technique on commercial glass façade, showing extraction stage

Stage 03 — Extraction · Golf Course Road, Gurgaon

02 /

Every Rope.
Every Anchor.
Documented.

A facility manager's duty of care doesn't end at the building perimeter. We provide full method statements, risk assessments, and insurance certificates before any crew sets foot on your roof. If your HSE officer asks for it, we have it.

IRATA Grade II

Industrial Rope Access Trade Association

All supervisors hold active Grade II certifications, renewed every 3 years with mandatory re-assessment.

WFSG Compliant

Window & Façade Services Guild

Adherence to WFSG Code of Practice for high-rise façade access, risk assessment documentation, and method statements.

₹5 Cr Public Liability

New India Assurance — Active Policy

Full public liability and employer's liability cover for every site. Certificate available on request before any mobilisation.

IS 3521 Compliant

Bureau of Indian Standards

Equipment, harness systems, and anchor points meet IS 3521 industrial safety belt standards for working at height.

Rope access technician wearing full harness and helmet performing safety check before descending glass tower façade
Pre-descent harness check
Safety anchor point and rope rigging setup on rooftop edge before rope access work begins
Rooftop anchor rigging
Two technicians performing buddy-check safety verification on harness equipment at height
Buddy-check protocol

Zero recordable incidents

since 2019 · 850+ buildings · 4.2 lakh sq ft cleaned annually

Request Certificates
03 /

The Results
Speak Clearly.

We manage eleven buildings on Golf Course Road. Before Gleam, every vendor gave us the same story: bucket trucks, three-day shutdowns, tenants complaining about blocked sightlines. Gleam mobilised in four hours, rigged from the roof, and had Building 7's entire curtain wall done by 6 PM. The facilities committee didn't even know it happened until they looked out their windows the next morning.

We've renewed the AMC three years running. The before-and-after documentation they provide is exactly what the building owner wants to see at every quarterly review.

Rajesh Malhotra, Senior Facility Manager at Prestige Golf Course IT Park, Gurgaon

Rajesh Malhotra

Senior Facility Manager · Prestige Golf Course IT Park

AMC Client — 3 Years Continuous

Drag to compare · Building 7, Golf Course Road

04 /

What Moves
The Number.

There's no fixed per-pane rate that works across a 4-storey Defence Colony bungalow and a 38-storey Aerocity tower. Three variables drive every quote: how many floors, what glass coating, and how hard the access is. Use the estimator below to orient yourself before we visit.

12F
1F50F

Estimate Orientation

+18%

Access surcharge

Glass multiplier

MEWP or rope depending on site · Plain Float glass. Final pricing depends on glass area (sq ft), access equipment availability, and frequency. The site survey locks in the exact number.

Get Exact Quote

Access Difficulty Scale

1–5 floorsBase rate

Ladder / MEWP accessible

6–15 floors+18%

MEWP or rope depending on site

16–30 floors+35%

Rope access mandatory

31+ floors+50%

Rope access + additional rigging

AMC Discounts Available

Annual Maintenance Contracts covering quarterly or bi-annual cleans attract 12–22% off the per-visit rate, plus priority scheduling before Diwali and monsoon season.

Not Ready to Book Yet?

Download Our AMC Rate Card

Per-visit and annual rates across building categories — from a 4-floor bungalow in Defence Colony to a 35-floor IT park in Aerocity. No obligation, no follow-up call unless you ask.

We'll Come.
We'll Measure.
You'll Know
The Exact Cost.

Our estimator visits your site, measures the glass area, assesses access complexity, and delivers a line-item quote within 24 hours. No ballpark figures — just a number you can put in a committee paper.

Survey completed in under 90 minutes

Quote delivered within 24 hours

IRATA-certified crew for every project

Zero deposit required to book

Chat on WhatsApp

Site Survey Request

Facility managers think in buildings, not postcodes.

10 floors
150

No deposit required · Quote within 24 hours · Delhi NCR only